K-Factor Results
- 1. Measured BD: BD = (52 + 52) - 100 = 4.000 mm
- 2. OSSB: tan(45°) × (3 + 2) = 5.0000 mm
- 3. Derived BA: BA = (2 × 5.0000) - 4.000 = 6.000 mm
- 4. Solved K: K = [(180 × 6.000)/(π × 90) - 3] / 2 = 0.4099
K = t / T (Distance from inside surface to neutral axis divided by thickness)
How to Calibrate K-Factor with a Test Bend Coupon
Cut Test Coupon
Shear or laser cut a rectangular blank to an exact known length (e.g. exactly 100.0 mm or 4.000 in). Measure with calipers to verify.
Bend on Press Brake
Form a standard 90° bend using your production punch, V-die, and target sheet material. Allow the part to spring back.
Measure Formed Legs
Measure outside flange lengths L1 and L2 to the outside apex using a digital vernier caliper, and measure actual inside radius R.
Input & Back-Solve K
Enter measurements above. The calculator will back-solve the exact K-factor and Y-factor for your tooling to program into CAD/CAM.
What K-Factor Really Means
K-factor is the ratio of neutral axis distance (t) to the full sheet thickness (T). In pure elastic deformation, K = 0.50 (the centerline). When metal undergoes plastic forming in a press brake, compression on the inside causes cross-sectional thinning and strain hardening, shifting the neutral axis inward (K < 0.50).
BD = (L1 + L2) − L_flatOSSB = tan(A / 2) × (R + T)BA = (2 × OSSB) − BDK = [ (180 × BA) / (π × A) − R ] / T
Empirical K-Factor Guidelines
| R / T Ratio | Soft Materials (Alum/Copper) | Hard Materials (Steel/SS) |
|---|---|---|
| R < 1 × T | 0.33 – 0.38 | 0.30 – 0.35 |
| 1 × T ≤ R ≤ 3 × T | 0.38 – 0.42 | 0.40 – 0.44 |
| R > 3 × T | 0.42 – 0.48 | 0.44 – 0.48 |
Frequently Asked Questions (FAQ)
Can K-factor be greater than 0.50?
No. Mathematically and physically, in standard sheet metal bending the neutral axis always shifts inward toward the compressive inside face, meaning K is always between 0.25 and 0.50. If test coupon math yields K > 0.50, your caliper measurements of L1 or L2 are inaccurate.
What is the difference between K-Factor and Y-Factor?
Y-Factor is an alternative constant used by PTC Creo / Pro-Engineer. It is directly related to K-Factor by the formula: Y = K × (π / 2). If K = 0.40, Y = 0.6283.