Sheet Metal K-Factor Calculator

Calculate the exact K-Factor and Y-Factor by reverse-engineering a physical test bend coupon or from direct neutral axis depth.

K-Factor Results

Calculated K-Factor (K)
0.4000
Corresponding Y-Factor (Y = K × π/2) 0.6283
Neutral Axis Depth (t = K × T) 0.8000 mm
Derived Bend Allowance (BA) 5.9690 mm
Plastic Strain & K-Factor K = t / T
Centerline (0.5T) Neutral Axis (t = K×T) Tension (+) Compression (−) T
Core Definition: K = t / T (Distance from inside surface to neutral axis divided by thickness)

How to Calibrate K-Factor with a Test Bend Coupon

01

Cut Test Coupon

Shear or laser cut a rectangular blank to an exact known length (e.g. exactly 100.0 mm or 4.000 in). Measure with calipers to verify.

02

Bend on Press Brake

Form a standard 90° bend using your production punch, V-die, and target sheet material. Allow the part to spring back.

03

Measure Formed Legs

Measure outside flange lengths L1 and L2 to the outside apex using a digital vernier caliper, and measure actual inside radius R.

04

Input & Back-Solve K

Enter measurements above. The calculator will back-solve the exact K-factor and Y-factor for your tooling to program into CAD/CAM.

What K-Factor Really Means

K-factor is the ratio of neutral axis distance (t) to the full sheet thickness (T). In pure elastic deformation, K = 0.50 (the centerline). When metal undergoes plastic forming in a press brake, compression on the inside causes cross-sectional thinning and strain hardening, shifting the neutral axis inward (K < 0.50).

Reverse-Calculation Derivations:
BD = (L1 + L2) − L_flat
OSSB = tan(A / 2) × (R + T)
BA = (2 × OSSB) − BD
K = [ (180 × BA) / (π × A) − R ] / T

Empirical K-Factor Guidelines

R / T Ratio Soft Materials (Alum/Copper) Hard Materials (Steel/SS)
R < 1 × T0.33 – 0.380.30 – 0.35
1 × T ≤ R ≤ 3 × T0.38 – 0.420.40 – 0.44
R > 3 × T0.42 – 0.480.44 – 0.48
💡 SolidWorks / Inventor Tip: Both SolidWorks and Autodesk Inventor accept direct K-Factor input in their sheet metal gauge tables. Setting this verified value guarantees flat pattern laser blanks match finished formed dimensions.

Frequently Asked Questions (FAQ)

Can K-factor be greater than 0.50?

No. Mathematically and physically, in standard sheet metal bending the neutral axis always shifts inward toward the compressive inside face, meaning K is always between 0.25 and 0.50. If test coupon math yields K > 0.50, your caliper measurements of L1 or L2 are inaccurate.

What is the difference between K-Factor and Y-Factor?

Y-Factor is an alternative constant used by PTC Creo / Pro-Engineer. It is directly related to K-Factor by the formula: Y = K × (π / 2). If K = 0.40, Y = 0.6283.

Engineering Disclaimer: K-factor varies with material rolling direction, punch nose sharpness, and V-die ratio. Physical coupon calibration is strongly advised for high-precision aerospace and medical sheet metal fabrication.